Electronic Program Start Ballast (for Preheat Start Lamps), 425mA nominal lamp current with an Arc voltage between 92V-176V, Input voltage of 100-240Vac, for 1 41W-75W Lamp, 50-60Hz, wire harness connector (included with ballasts).
APPLICATION:– Maximum Case Temperature 194F/90C– Maximum Starting Temperature 122F/50C– Minimum Starting Temperature 0F/-18C– Lamp Starts> 50,000 Starts– Remote Mounting 20 ft.Max.Lead Length,18AWG Shielded or in Conduit
SAFETY & CERTIFICATIONS:– UL 935 (Class P,Type CC,Type1 Outdoor,Type HL)– cULus,CE, CCC– Leakage Current to UL/935 Standard– EN 61347-1:2001– EN 61347-2-1:2001– EN 61347-2-3:2000– RoHS EU Directive 2011/65/EU&2015/863 Amendment (RoHS 3 )– Anti -Arcing– Output Short Circuit Protection– Output Open Circuit Protection– Restrike Attempts = 2– Inrush Current <40 AMPS– Meets ANSI Standard C62.41 for Transient Protection– Meets ANSI Standard C82.11 for Ballast Requirments– Sound Rated A
Specs
| Ballast Type | Electronic |
| Starting Method | Program Start |
| Color | White |
| Input Voltage | 100-240Vac 10% |
| Lamp Connection | Parallel |
| Input Frequency | 50-60Hz |
| Housing | 22ga 5052 H43 Aluminum |
Lamp Compatibility
– G36T5/4P/SE– G64T5/4P/SE– G64T5L/4– GCL36T5L/Cell– GCL36T5VH/Cell– GCL793T5L/Cell– GCL793T5VH/Cell– GPH793T5L– GPH793T5L/4– GPH793T5L/4P– GPH793T5VH/4– GPH810T5L/4– GPH810T5VH/4– GPH843T5L– GPH843T5VH– GPH1148T5VH– GPH1148T5L– GPH1554T5L– GPH1554T5VH– GPH1630T5L– GPH1630T5VH– LTC40T5SE– LTC64T5SE– TUV 36 4P-SE T5– TUV 64 4P-SE T5
Data Sheet
Manual:
PAQ164G6MV Data Sheet